IR29 Transmitter

Ex-proof IR transmitter for combustible gases


If flammable gases and vapors need to be monitored in Ex zones, the IR29 transmitter is a reliable and robust solution. The IR29 uses an analog (4-20 mA) signal to transmit measured values and status information. Gases are monitored either on-site by diffusion or via unpressurized gas supply with a flow adapter. In combination with GfG's reliable controllers, it can be installed in new gas detection systems or retrofitted into existing ones.

The IR29 uses non-dispersive infrared (NDIR) sensor technology to detect combustible gases and vapors. Our patented 4-beam and 4-wavelength technology with gold-plated mirror optics, which does not require any beam splitters, is used to ensure selective measurement results without false alarms. The installed infrared sensors also enable measurements above the lower explosion limit (LEL), do not require oxygen and are not susceptible to sensor poisons. The long-life sensors make the IR29 a permanently reliable solution for detecting a wide range of combustible gases and vapors in the 0 to 100 % LEL measuring range. Its automatic temperature compensation and the linearization of the measurement signals ensure high measurement accuracy.

Communication and service
The IR29 communicates via the 4-20 mA industry standard signal. Two status LEDs are used to indicate its operation status. Service and adjustments can be carried out on site using the optional RC2 remote control (one-person adjustment). The transmitter's self-monitoring function increases the device safety between maintenance intervals. Measured values and incidents are automatically recorded by the transmitter in an internal ring buffer. Test gases for function tests and adjustments can be inserted through a calibration adapter. 

Safety and instrument protection
The IR29 is ATEX-certified for use in Ex zone 1. It complies with the increased safety "e" and encapsulation "m" standards. The housing made of V4A stainless steel and poly-carbonate is protected against ingress of dust and water (protection class: IP67). Accessories include a guard plate and dust filter.

 

Key features at a glance:


General information:

  • Measuring principle: infrared (IR)
  • For combustible gases and vapors
  • Not susceptible to sensor poisons
  • Expected sensor lifetime: 6 years
  • Signal transmission: 4-20 mA
  • Protection class: IP67
  • Integrated data logger

Approvals / Certifications:

  • ATEX certification: II 2G Ex eb mb ib [ib] IIC T4 Gb

Optionally available:

  • Pressure and humidity sensors, ex-proof control unit RC2, impact protection, flow adapter, calibration adapter, protection plate, dust filter, weatherproof housing, flow adapter

Detectable gases

LEL combustible gases
C2H2 Acetylene
C2H4 Ethylene
C2H6O Ethanol
C3H8 Propane
C3H8O n-Propanol
C4H10 n-Butane
CH4 Methane
   
Other gases on request.

Downloads

Extensions and accessories

Weatherproof housing


Weatherproof housing for various transmitters
» more

Test gases


Find an overview of our test gases here
» more

Accessories IR29


Find the complete list of accessories for the IR29 here
» download PDF

Our experts are happy to answer your questions! How to find us